TOTAL PC SYSTEMS
Acasa Despre noi Contact Cupoane cadou Promotii Harta site
Cautare: Cautare avansata
Acasa    
Catalog    
Contul meu    
Cosul meu    
EVGA
AcasaUPSUPS, APOLLO, 1065VC, Line Interactive 650VA  
UPS, APOLLO, 1065VC, Line Interactive 650VA

Vezi imagine marita

COD: 1065VC

Pret: 206,80 RON (taxe incluse)
10 zile
207 puncte valorice
In Stoc
12 luni

Descriere
Recomanda
Comentarii
Brand Apollo
Power Level 650VA / 350W
Output Voltage 100V/110V/115V/120V Selectable
or 200V/220V/230V/240V Selectable
Voltage Waveform Step wave
Crest factor 2 : 1
Output frequency 50 / 60 Hz
Regulation (Nominal) 10 percent (AVR)
Regulation (Battery mode) 5 percent of selected output voltage
Transfer time Blackout: 5ms typical
Brownout: 5ms typical
Battery mode to Normal mode: 3ms typical
Overprotection Over load alarm level 100 - 120 percent
Over load shutdown level 120 - 190 percent
(Adjustable with the remote set-up software)
Input 650VA
Nominal Voltage 100V/110V/115V/120V Selectable
or 200V/220V/230V/240V Selectable
Input frequency 47Hz - 65Hz 50/60Hz auto-sensing
Efficiency (Normal Mode) 97 percent
Overprotection By reset-able over current protector
Voltage Range -33 - +28 percent
AVR Range Buck mode: +9 percent for selected nominal voltage
Boost mode: -9 percent for selected nominal voltage
Enhanced Boost: -22 percent for selected nominal voltage
Surge Protection 115 Joules
Battery
Battery type Maintenance –free sealed valve-regulated Lead-Acid
Voltage 12V / 7Ah x 1pc
Typical back-up time
Half-Load
12-15 minutes depending on load connected
Typical back-up time
Full-Load
3.5 - 4 minutes depending on load connected
Charcing method Smart pulse charging with two charging modes
Quick charging when battery is not fully charged trickle
charging when battery is 90 percent fully charged.
Charging time 5 - 8 hours
Average charging current 0.6 A
Average charging voltage
for each Battery
Quick charging mode: 14V maximum
Trickle charging mode: 13.2V-13.9V adjustable by using the setting software
Protection Over charging voltage protection.(CPU control + Circuit control)
Thermo protection. (CPU control)
When temperature inside UPS is over 45 degree C charger will stop charging for
2.5 minutes followed by an 1.5 minutes charging the cycle will repeat
until the temperate is lower than 44 degree C.
Monitoring Smart monitoring for failed battery or battery open circuit detection and warning
Auto-detect every time when power on and auto repeat the detection every 6 days.
Porturi RS232 (optional for USB) RJ45 (Surge Protection)
Control Panel LCD or LED Selectable
Alarm On battery alarm: Low battery alarm Battery over voltage alarm
Over load alarm: Short-circuit alarm Thermal alarm
Green Mode Function 1-14 percent of full load (adjustable with the setting software)
The default setting is OFF.
Garantie 1 an

editor1

"
  
*
  
  
*

Sistemul de protectie anti-spam este activat. Te rugam sa introduci caracterele din aceasta imagine.
Toate literele vor fi scrise cu majuscule.

  Redeseneaza

Caractere: 

Continut site

Continutul site-ului etotalpc.ro a fost alcatuit in principal cu informatiile de pe site-urile producatorilor. De aceea etotalpc.ro nu isi asuma responsabilitatea pentru descrierile produselor prezentate in magazinul virtual, acestea fiind identice cu cele puse la dispozitia noastra de catre reprezentantii fiecarei marci. Totusi s-au depus eforturi mari pentru a minimaliza toate greselile care pot aparea din editarea electronica sau manuala a informatiilor prezentate. De asemenea, imaginile sunt prezentate pe site cu titlu de exemplu, iar produsele livrate, pot diferi de imagini in orice mod, datorita modificarii caracteristicilor, design-ului fara notificare prealabila de catre producatori.

Preturile afisate sunt valabile doar pentru comenzile online si pot fi modificate fara o notificare prealabila.

Yahoo Messenger

incarcare ... incarcare ...